Do you need any help? We are here to help!
Please contact us to provide you with satisfactory products and become a reliable supplier and service provider in the industry
Regarding Inaccurate Tension, Over-tensioning, and Under-tensioning Solutions
Release time:
2025-07-19
Inaccurate pressure gauge readings, oil pump leaks, uncalibrated jack, and significant reading deviations.
Symptoms:
Inaccurate pressure gauge readings, oil pump leaks, uncalibrated jack, and significant reading deviations.
Causes:
- Jack and pressure gauge not calibrated on schedule
- Air ingress in the hydraulic system, aged seals
- Incorrect conversion of pressure gauge readings
Solution:
1. Calibrate the jack and pressure gauge as a set; recalibration is required every 6 months or after 200 tensioning cycles.
2. Bleed the system and inspect seals before tensioning; replace oil seals immediately if leakage is detected.
3. Calculate tensioning force strictly according to the calibration curve; do not rely on experience.
Latest News
The Overall Outlook for the International Bridge Engineering Industry
The bridge industry is transitioning from labor-intensive to technology-intensive, green and smart, and asset-service oriented. Chinese enterprises lead globally in ultra-long-span bridges, smart construction, and cost control, with vast potential for overseas expansion and the export of standards.
2026-05-28
Common Safety Hazards (Important to Note)
1. Personnel at the tensioning end → Do not stand directly behind the jack 2. Stranding rebound → Install protective barriers
2026-04-16
Solutions to Common Issues with Front Car Jacks (the 27t/30t models you asked about earlier)
Apply anchor release agent and replace the tool anchor regularly; retract slowly.
2026-03-19
Excessive retraction of the steel strand
Replace with qualified clamping plates Adjust the height of the stop plate
2026-01-21
Solutions for Poorly Compacted Grout, Voids, and Grout Leakage in Ducts
Ensure accurate cement slurry mix proportions and control the slump between 14 and 18 seconds. Use vacuum-assisted grouting with a negative pressure of -0.06 to -0.08 MPa.
2025-12-13
Solution for Asynchronous Tensioning (Tensioning at Both Ends)
Significant pressure difference between the two ends; the elongation values do not match.
2025-11-15