Do you need any help? We are here to help!
Please contact us to provide you with satisfactory products and become a reliable supplier and service provider in the industry
Solutions for Poorly Compacted Grout, Voids, and Grout Leakage in Ducts
Release time:
2025-12-13
Ensure accurate cement slurry mix proportions and control the slump between 14 and 18 seconds. Use vacuum-assisted grouting with a negative pressure of -0.06 to -0.08 MPa.
Major Quality Risks in the Post-Tensioning Method
Solutions:
1. Ensure accurate cement slurry mix proportions and control the slump between 14 and 18 seconds.
2. Use vacuum-assisted grouting with a negative pressure of -0.06 to -0.08 MPa.
3. Seal the grout outlet only after the consistency of the grout has stabilized.
4. Arrange the vent pipes and grout discharge pipes reasonably, ensuring venting at the highest points.
Latest News
The Overall Outlook for the International Bridge Engineering Industry
The bridge industry is transitioning from labor-intensive to technology-intensive, green and smart, and asset-service oriented. Chinese enterprises lead globally in ultra-long-span bridges, smart construction, and cost control, with vast potential for overseas expansion and the export of standards.
2026-05-28
Common Safety Hazards (Important to Note)
1. Personnel at the tensioning end → Do not stand directly behind the jack 2. Stranding rebound → Install protective barriers
2026-04-16
Solutions to Common Issues with Front Car Jacks (the 27t/30t models you asked about earlier)
Apply anchor release agent and replace the tool anchor regularly; retract slowly.
2026-03-19
Excessive retraction of the steel strand
Replace with qualified clamping plates Adjust the height of the stop plate
2026-01-21
Solutions for Poorly Compacted Grout, Voids, and Grout Leakage in Ducts
Ensure accurate cement slurry mix proportions and control the slump between 14 and 18 seconds. Use vacuum-assisted grouting with a negative pressure of -0.06 to -0.08 MPa.
2025-12-13
Solution for Asynchronous Tensioning (Tensioning at Both Ends)
Significant pressure difference between the two ends; the elongation values do not match.
2025-11-15