Prototype with dual circuits
Classification :
PRODUCT DETAILS
Solenoid-operated single-circuit oil pump = a hydraulic power unit featuring a single oil circuit (with only one high-pressure outlet and return line) and an integrated solenoid directional control/unloading valve, specifically designed for precise, electronically controlled, and pressure-maintaining operation of a single actuator (single jack or single cylinder).
Core Structure (Simplified)
- Pump Body: Plunger pump/gear pump (plunger pumps are commonly used for high pressure, 50–80 MPa)
- Solenoid Valve: 2-way/3-way (reversing/unloading/pressure holding)
- Single Oil Circuit: Only one set of inlet/outlet ports, no parallel branches
- Accessories: Relief valve, check valve, pressure gauge, oil tank, motor+
Core Applications (Distinguished from Dual-Circuit Systems)
- Precise single-actuator control: Single-jack tensioning, single-cylinder lifting/pressure holding
- Electronically controlled start/stop, directional control, and unloading: PLC/button control with millisecond-level response and no manual directional control lag
- Pressure holding/load holding: Pressure lock upon power failure or loss, suitable for prestressing tensioning and mold pressure holding
- Energy-saving unloading: Solenoid valves open during standby, allowing the pump to idle, thereby reducing energy consumption and heat generation
- Single-strand/single-point operation: Does not support synchronized tensioning with multiple jacks
Typical Applications (Best Match)
1. Prestressing Construction (Most Common)
- Single-strand prestressing (box girders/hollow slabs/single-hole prestressing for pipe piles)
- Post-tensioning: single-hole anchoring, single-strand anchor cable/bolt tensioning
- Small precast components: pre-tensioning with single-jack tensioning
2. Small Hydraulic Equipment
- Single-cylinder hydraulic presses, single-cylinder pipe jacking machines, single-cylinder crimping machines
- Mold closing/holding pressure, single-cylinder lifting/alignment
- Hydraulic clamps, single-cylinder locking devices
3. Construction/Geotechnical/Water Resources
- Tensioning of single anchor bolts for slopes, tensioning of single anchor cables for excavation pits
- Single-cylinder opening/closing of small gates, single-cylinder water-stopping thrust
- Single-cylinder installation/jacking of equipment, single-cylinder alignment
4. Industrial Automation
- Single-station hydraulic fixtures, single-cylinder positioning/clamping
- Single-cylinder conveying/lifting, single-cylinder test benches
Quick Overview of Advantages and Disadvantages
✅ Advantages
- Simple structure, low cost, and easy maintenance
- Precise electronic control, fast response, and stable pressure (±1.5%)
- Reliable pressure maintenance, suitable for single-action/single-actuator applications
- Compact size, suitable for confined spaces
❌ Disadvantages
- Single-circuit design; cannot synchronize multiple jacks
- Lower efficiency than multi-circuit systems; not suitable for high-flow or multi-action applications
Key Selection Criteria (Quick Reference)
- Pressure: 50/63/80 MPa (63/80 MPa commonly used for prestressing)
- Flow Rate: 2–6 L/min (lower flow rates provide greater stability)
- Solenoid Valve: DC 24 V (common), AC 380 V
- Configuration: Single ram (YCW100–600 kN), single cylinder
- Control: Manual button/PLC/remote control
Differences from Dual-Circuit Pumps
- Single-circuit: 1 oil circuit, single ram, single-action, good pressure holding, cost-effective
- Dual-circuit: 2 oil circuits, dual rams in sync, bidirectional action, high efficiency, higher cost
| Motor Power | Voltage | Standard Configuration Operating Valve | Oil Tank Capacity |
|---|---|---|---|
| 0.75KW | 220V/380V | Manual Double-Acting | 16L/8L |
| Manual Single-Acting | 16L/8L | ||
| Solenoid Single-Acting | 16L/8L | ||
| Solenoid Double-Acting | 16L/8L | ||
| 1.1KW | 220V/380V | Manual Double-Acting | 16L/8L |
| Manual Single-Acting | 16L/8L | ||
| Solenoid Single-Acting | 16L/8L | ||
| Solenoid Double-Acting | 16L/8L | ||
| 1.5KW | 220V/380V | Manual Double-Acting | 36L/40L |
| Manual Single-Acting | 36L/40L | ||
| Solenoid Single-Acting | 36L/40L | ||
| Solenoid Double-Acting | 36L/40L | ||
| 2.2KW | 220V/380V | Manual Double-Acting | 40L/36L |
| Manual Single-Acting | 40L/36L | ||
| Solenoid Single-Acting | 40L/36L | ||
| Solenoid Double-Acting | 40L/36L |
CUSTOMER VISIT
Our products sell well throughout China and are exported to countries and regions such as Cambodia, Malaysia, the Philippines, Dubai, and Colombia.
FACTORY WORKSHOP
With over 100 employees and more than 30 advanced processing and testing equipment, including CNC machine tools, CNC drilling machines, radial drilling machines, and cutting machines, the company boasts stable production capacity.
Factory workshop
Factory workshop
Factory workshop
Factory workshop
Factory workshop
Factory workshop
Factory workshop
Factory workshop
APPLICATION FIELD
Railway
Municipal
Airport
Water conservancy and hydropower
Bridge
Oil Extraction
FAQ
Q:How long is your delivery time?
Q:If accept OEM/ODM service to made product as per customer offering drawing?
Q:How can we trust your quality?
Q:Can the Buyers Visit the Factory?
RELATED PRODUCTS
GET A FREE QUOTE